• Normal Font Size
    Normal Font Size
    Normal Font Size
    Normal Font Size
    Normal Font Size
GJUST logo
GJUST Hisar, Haryana

CIL Lab

Home / Facilities / CIL Lab

Dr. APJ Abdul Kalam Central Instrumentation Laboratory (CIL)
Prof. Munish Ahuja
   Director
   Department of Pharmaceutical Sciences
   cilgju@gmail.com
   01662-263352
   GJUST, Hisar

Prof. C.P. Kaushik
   Deputy Director
   Department of Chemistry
   cpkaushik4@gjust.org
   01662-263398
   GJUST, Hisar

Prof. Manish Kumar
   Deputy Director
   manishgju@gjust.org
   01662-263516
   GJUST, Hisar


The Dr. APJ Abdul Kalam Central Instrumentation Laboratory is nestled within the vibrant campus of Guru Jambheshwar University of Science and Technology,Hisar. Since its inception in the year 2000, this cutting-edge facility has been a beacon for students, research scholars, and teachers actively involved in groundbreaking R&D pursuits across the dynamic realms of Science, Technology & Engineering. Our state-of-the-art laboratory, currently housed in a modern structure spanning an area of 7212 sq.ft and adorned with modern amenities, is tailored to inspire scientific excellence. The CIL cater to the needs of the students, research scholar and teachers of this university as well as other educational institute and industry in order to promote research activities. Researchers from about 105 academic institutions and research centers nationwide have already experienced the transformative capabilities of our facilities. Over the years, the laboratory has acquired sophisticated equipment funded by the DST under the PURSE program and MHRD under the RUSA scheme. Apart from supporting researchers through sample testing, the CIL conducts training programs for skill upgradation of research scholars and capability enhancement of technical staff. The CIL cater to the needs of the students, research scholar and teachers of this university as well as other educational institute and industry in order to promote research activities.

 

Sr. No.Equipment NameModel/MakeSpecification
1FT-IR SpectrophotometerSpectrum Two/ Perkin ElmerScan range of 4000- 400cm-1
2Atomic Absorption Spectrophotometer (AAS)GBC 932+Elemental Determination in ppm Range
3Microwave Plasma Atomic Emissions Spectrometer (MP-AES) Agilent Technology 4210/ AgilentElemental Determination in ppm & ppb
4Differential Scanning Calorimeter (DSC)Discovery 25/ TA Instruments WatersRange-90oc+500oc & Modulated DSC for the most efficient separation of complex thermal events
5FT-NMR SpectrometerAvance III, 400MHz: BrukerSolvents - CDCl3 & DMSO -d6, D2O 1H-NMR, 13C-NMR, 31P-NMR, 19F-NMR, 119Sn-NMR, 29Si-NMR
6Microwave SynthesizerMonowave 200/ Anton PaarMix. operating temperature -260oC & pressure up to 20 bar
7Mass Spectrometer - Liquid Chromatography Mass Spectrometry (LCMS)SCIEX TripleTOF 5600 and 5600+ /SCIEXMass range- 100 to 2000Da Solvents - Methanol, Acetonitrile, Water LC Column- Phenomenex, Synergi, 4?m, C18 Fusion RP 80?, Dimension-50x2mm
8Ultra High Performance Liquid Chromatoraphy (UHPLC)Nexera 2 UHPLC/ShimadzuDetector : PDA RID-20A Refractive Index Detector RF-20A Spectrofluorometric Detector Columns : Shim Pack GIST C18 2?m, Dimensions: 2.1x150mm and 2.1x100mm
9High Resolution Field Emission Scanning Electron Microscope with EDS (FE-SEM)7610F Plus/JEOLResolution of 0.8nm @ 15kV 1.0nm @ 1 kV
10Raman SpectrometerAlpha300/ WITecSpectra range 0cm-1 to 4000 cm-1 XYZ Mapping Capabilities Laser 532 nm, Laser 785 nm with visible power
11Research Grade Advance Rheometer SystemMCR 302e MODULAR COMPACT RHEOMETER/ Anton PaarTorque Range :- Min. (Rotation): 1.00 nano Nm, Min. (Oscillation): 0.5nano Nm & Max:230 Milli Nm Speed Range: 0 to 314 rad/s Frequency Range: 10e-7 to 628 rad/s Temperature Range: 0 to 400 ?C Normal Force : 0.005 To 50 N
12Multipurpose Versatile XRD System (XRD)SmartLab 3kW/ RigakuPowder XRD, Thin Film XRD 2? range 1? to 157? Angle speed per minute 2? to 10?
13Flash ChromatographPure C-810/ BUCHI250mL/min flow rate at max. 50 bar, 4 independent solvent lines, Binary, linear, step and isocratic gradients, 200 - 800nm wavelength range
14UV- SpectrometerUV-1800/ ShimadzuRange: 190-800nm and only liquid sample

 

 

All the communication should be addressed to:

Director
Dr. APJ Abdul Kalam Central Instrumentation Laboratory (CIL)
Guru Jambheshwar University of Science and Technology
Hisar -125001, Haryana
Phone: 01662-263352: 263667
E-mail: cilgju@gmail.com
Website: www.gjust.ac.in

Dr. APJ Abdul Kalam Central Instrumentation Laboratory
S.NO. Subject Detail
NOTICE INVITING TENDER View
Nuclear Magnetic Resonance -400MHz (NMR) View
Raman Spectrometer View
Multipurpose Versatile XRD System (XRD) View
Differential Scanning Calorimeter (DSC) View
Field Emission Scanning Electron Microscope (FESEM) View
Liquid Chromatography Mass Spectrometer (LCMS) View
Ultra High Performance Liquid Chromatography (UHPLC) View
Rheometer View
Fourier-Transform Infrared Spectrophotometer (FTIR) View
Microwave Synthesizer View
Charges for sample analysis View
Proforma for Samples View